The Fox LCD Series
The Uninterruptible Power System of Fox LCD series provides you with the advanced technology in the modern word to protect computer, telecommunication instrument, electrical facilities, medical equipment, and any other important equipment from corruption or loss of data due to power line disturbance. The philosophy of design in power stage is through the combination of a Double-Conversion circuit to create continuous power for the load. It offers complete protection against a variety of power problems, such as blackout, brownout, electrical noise, spikes, sags, surges, voltage transient, and frequency variation.
Features
‧ Double Conversion Design Provides High Reliability and Efficiency.
‧ High Frequency Designs to Lower the Size and Weight.
‧ Intelligent Microprocessor Control.
‧ True Sine Wave Output.
‧ User Configurable Output Voltage.
‧ Smart Battery Reminder.
‧ Self-Diagnostic Function can Provide Information for Troubleshooting Reference.
‧ RJ11 Data/Fax Modem Connection Provides Surge Protection from Telephone.
‧ 100 Base T RJ45 Connection Provides Surge and Spike Protection for Network.
‧ True RS232 Signal for Power Management Software.
‧ Optional SNMP/HTTP Card Connectivity for Remote Monitoring.
Specification
|
Model
|
1000
|
2000
|
3000
|
1000L
|
2000L
|
3000L
|
|
|
Capacity (VA/W)
|
1000VA/700W
|
2000VA/1400W
|
3000VA/2100W
|
1000VA/700W
|
2000VA/1400W
|
3000VA/2100W
|
|
|
Rated Power Factor
|
0.7
|
|
AC Input
|
|
Number of Phase
|
Single phase
|
|
Voltage Range
|
160~276Vac for 220Vac (It can extend to 120Vac, if the output load is less than 40% load. )
80~138Vac for 120Vac (It can extend to 60Vac, if the output load is less than 40% load.)
|
|
Frequency Range
|
50/60Hz
60/50Hz
|
|
AC Output
|
|
Number of Phase
|
Single Phase
|
|
Nominal Voltage
|
208/220/230/240Vac
110/115/120/127Vac
|
|
Waveform
|
True Sine Wave
|
|
Voltage Regulation
|
@ Resistive Load ±2%, @ Non-linear Load ±3%
|
|
Harmonic Distrotion
|
THD<3% of at full Linear Lad, <5% at Full Non-linear Load
|
|
Load Crest Factor Ratio
|
3:1
|
|
Frequency Regulation
|
± 0.3Hz (Free Running)
|
|
Over Load Capacity
|
105~125% ±10% for 1 minute, 126~150% ±10% for 10 seconds, > 150% ±10% Shutdown Immediately.
|
|
Transfer Time
|
0 ms (Zero Transfer)
|
|
Output Receptacles
|
4pcs IEC
NEMA 5-15R x 4
|
6pcs IEC
NEMA 5-15R x 6 + NEMA 5-20
|
6pcs IEC
NEMA 5-15R x 6 + NEMA L5-30
|
4pcs IEC
NEMA 5-15R x 4
|
6pcs IEC
NEMA 5-15R x 6 + NEMA 5-20
|
6pcs IEC
NEMA 5-15R x 6 + NEMA L5-30
|
|
|
DC start
|
Yes
|
|
Battery
|
|
Quantity
|
2
|
6
|
8
|
NA
|
NA
|
NA
|
|
|
Battery Voltage
|
24
|
72
|
96
|
24
|
72
|
96
|
|
|
Battery Type
|
Sealed, Maintenance-free lead acid)
|
|
Run Time
|
3 Minutes
|
4Minutes
|
4.5 Minutes
|
|
Recharge Time
|
8 hours to 90%(STD models)
|
Depends on the External Battery
|
|
Interface
|
|
Communications
|
RS232/USB (Optional)
|
|
Protocol
|
Megatec Protocol
|
|
Compatibility of Bundled software
|
UPSilion 2000 for Novell Netware, Windows series Operation Systems, Linux and Free BSD ( Basic Version)
|
|
SNMP Capability
|
External SNMP Adapter( Optional)
|
|
Features
|
|
Protection
|
Overheat, Overload, Short-circuit, Surge,
|
|
Noise Suppression
|
Complies with EN50091-2
|
|
Spike Suppression
|
Complies with EN61000-4-5
|
|
Display
|
LCD display the UPS status, & Green LED indicate Normal model, Red LED indicate Fault model
|
|
Audible and Visual
|
Line Failure, Battery Low, Transfer to Bypass, Over Load, System Fault Condition
|
|
Agency
|
|
Marks
|
CE, BN60950, EN 50091-1-1
|
|
Other
|
|
Operating Temperature
|
0 ~ 40°C
|
|
Altitude
|
0~3000m
|
|
Humidity
|
95% RH Maximum, Non-Condensing
|
|
Audible Noise
|
<50 dBA @1m
|
|
Dimensions (W×D×H)mm
|
160 x 225.5 x 438
|
194 x 351 x 457
|
194 x 351 x 457.5
|
160 x 225.5 x 438
|
194 x 351 x 457
|
194 x 351 x 457.5
|
|
|
Weight (Kg)
|
12.6
|
27.5
|
31.4
|
8.3
|
15.8
|
16
|
|